Countertop Automated Cleaning System
Four Stage Automated Cleaning SystemThis automated precision four stage cleaning system is comprised of an ultrasonic wash, two ultrasonic immersion tanks with spray rinse, and a hot air dryer. Part transport is completed via an integrated part handling system done automatically per the pre-defined cleaning cycle.

Specifications
Wash/Rinse/Rinse | Dry | |
Inside Dimensions | 10"x7"x24" | 10"x7"x24" |
Overall Dimensions | 78"x32"x 97"L system total | 78"x32"x97"L system total |
Frequency | 40kHz standard (25, 68, 170 kHz available) | NA |
Power Requirements | 240V | 240V |
Ultrasonic Power | 500W Average / 1000W Peak | NA |
Heat Power | 1000W | 2000W |
Construction Material | Stainless Steel | Stainless Steel |
Automation PLC
- Transporting baskets through process
- Ultrasonic wash time
- Wash agitation (if selected)
- Rinse time
- Rinse DI fill time
- Rinse agitation (if selected)
- Rinse spray time
- Dryer lid open/close
- Blow-off time
- Dryer time
- Load and unload table sensors
- Unload alarm if basket is not removed
Sonic Touch®II
Advanced touch screen controls featuring VNC (iOS and Android) monitoring and control and UPC's newly patented LCS (cavitation level sensing) technology

Sonic Touch® II Features
- Countdown Timer for Ultrasonic operation
- 7-day programmable Timer for Heating system
- 7-day programmable Timer for Pump and filter system
- 7-day programmable Timer for Oil skimmer system
- Sweep Control for the Generator
- Elapsed Time Meter for ultrasonic Power monitoring
- Elapsed Time Meter for heating system monitoring
- Elapsed Time Meter for pump and filter system monitoring
- Elapsed Time Meter for oil skimmer system monitoring
- Patented LCS (Liquid Caviation Sensor) display- monitors cavitation activity levels for validation functions
- Frequency Display- displays frequency output for individual generators
- Power Output Display- displays accumulative output relative to number of generators
- Ultrasonic generator power output indicator alarm
- Ultrasonic generator power output indicator alarm log
- Data Recorder- continuous recording of system status in real time. Records while machine is on. Data can be stored on flash drives.
- Email/ SMS functions- can provide email or text notices for maintenance schedules or alerts selected by supervisor
- VNC Control Technology- Android/iOS capability using a VNC app for full system monitoring and control
- Password protected control for Level of User (Operator/Supervisor)
- Preventative Maintenance Timer/Schedule function
- SOVI ® (Sonic Output Validation Indicator) diagnostic system- validates operating condition of the system. Error code indicates fault.