Ultrasonic Mold & Die Cleaner
Custom Wash, Rinse, RP DipThis 3-Stage Ultrasonic Cleaning System consists of a three 320 gallon custom tanks. After the ultrasonic cleaning operation, a rinse process is completed before moving the part into a rust preventative dip tank. Between cleaning cycles, the solution is pump through a 20 micron filter working in tandem with an oil skimmer to remove debris and oils and prevent them from redistribution onto the cleaned part.

Inside Dimensions | 32"x18"x16"D |
Overall Dimensions | 51"x23"x40"H |
Frequency | 40kHz standard (25, 68, 170 kHz available) |
Power Requirements | 240V / 3P |
Ultrasonic Power | 8000 W Average / 16,000W Peak |
Heat Power | 7500 W |
Caster Feature | 4 heavy duty locking |
Construction Material | Stainless Steel |
Controls | Digital Timer and Digital Temperature |
Sonic Touch®II
Advanced touch screen controls featuring VNC (iOS and Android) monitoring and control and UPC's newly patented LCS (cavitation level sensing) technology

Sonic Touch® II Features
- Countdown Timer for Ultrasonic operation
- 7-day programmable Timer for Heating system
- 7-day programmable Timer for Pump and filter system
- 7-day programmable Timer for Oil skimmer system
- Sweep Control for the Generator
- Elapsed Time Meter for ultrasonic Power monitoring
- Elapsed Time Meter for heating system monitoring
- Elapsed Time Meter for pump and filter system monitoring
- Elapsed Time Meter for oil skimmer system monitoring
- Patented LCS (Liquid Caviation Sensor) display- monitors cavitation activity levels for validation functions
- Frequency Display- displays frequency output for individual generators
- Power Output Display- displays accumulative output relative to number of generators
- Ultrasonic generator power output indicator alarm
- Ultrasonic generator power output indicator alarm log
- Data Recorder- continuous recording of system status in real time. Records while machine is on. Data can be stored on flash drives.
- Email/ SMS functions- can provide email or text notices for maintenance schedules or alerts selected by supervisor
- VNC Control Technology- Android/iOS capability using a VNC app for full system monitoring and control
- Password protected control for Level of User (Operator/Supervisor)
- Preventative Maintenance Timer/Schedule function
- SOVI ® (Sonic Output Validation Indicator) diagnostic system- validates operating condition of the system. Error code indicates fault.